Direct air capture pulls carbon dioxide out of ordinary air using chemicals that selectively react with CO2 while letting nitrogen and oxygen pass through. According to the U.S. Department of Energy and the World Resources Institute, today's leading systems fall into two broad families: liquid solvent systems, which scrub air with a chemical "shower," and solid sorbent systems, which push air through filter-like materials that chemically bind CO2. Both follow the same two-step logic—capture, then regenerate—but they differ sharply in chemistry and, above all, in the heat needed to release the captured CO2. Liquid solvent regeneration runs at roughly 900°C; solid sorbents release CO2 at a small fraction of that temperature.

Climate change solutions: direct air capture technologyTo visually demonstrate the general process of direct air capture, providing a contextual overview of how air is processed and CO2 is captured.Watch on YouTube

Liquid Solvent DAC: Chemical Processes and Energy Needs

In a liquid solvent system, ambient air is drawn through a contactor where it passes through a shower of aqueous solution. As the University of Pennsylvania's Clean Energy Conversions Lab describes it, the air "passes through a 'shower' of liquid solvent where it reacts with a chemical dissolved in the water," commonly potassium hydroxide. The dissolved hydroxide reacts with CO2 and extracts it from the airstream, while the other components of air simply flow through and back to the atmosphere.

Regeneration is where the chemistry becomes elaborate. The capture liquid is cycled through a series of reactions in which calcium hydroxide reacts with the loaded solvent to form calcium carbonate. That carbonate is then fed through a high-temperature step—around 900°C, per WRI's technical overview—where it breaks down, isolating CO2 as a concentrated stream for transport and storage. The calcium oxide left behind is hydrated back into calcium hydroxide and reused. This closed loop restores the solvent for another capture cycle, but the calcination step's extreme heat demand defines the approach's energy budget.

Solid Sorbent DAC: Chemical Processes and Energy Needs

Solid sorbent systems replace the liquid shower with fixed filters. Air is pushed through solid sorbent material that is selectively reactive with CO2; the CO2 molecules chemically bind to the material's surface while the rest of the air passes through. The Department of Energy describes these as physical filters that chemically bind with CO2, saturating over time as capture proceeds.

The sorbent materials themselves are porous solids. As Atoco's technical overview by Anas Majdouli explains, next-generation systems increasingly rely on metal-organic frameworks (MOFs) and related reticular materials—engineered porous structures with a high affinity for CO2. Regeneration works by applying heat and/or a vacuum to the saturated filter, releasing the CO2 as a concentrated stream for geologic storage or use. Critically, this release occurs at far lower temperatures than solvent regeneration: WRI cites a range of roughly 80–120°C, and the University of Pennsylvania lab notes that heat applied at this stage both releases the CO2 and regenerates the filter for its next cycle.